Nubes Alto

Data Center in Moscow

In November 2022, we completed construction and put into commercial operation the Nubes Alto data center with a capacity of 4 MW and an area of ​​1360 m2. The site and buildings of the data center are owned by the company, located in the south of Moscow, in the Biryulyovo Vostochnoye district.

 

The resource base of the Nubes Alto data center will cover any IT needs of a mature business, support the growth and scaling of growing projects, and localize foreign IT infrastructure in Russia.

Alt

Rent of a machine room, dedicated part of the machine room, rack space.

Alt

Channels of connection. Optical fibers. Internet access and cloud platforms.

Alt

Workplace rental. Protection of racks by a protection (cage). Round the clock maintenance.

Tier III

Reliability

8 MW

Power input

1 360 м2

Total area

Data center technical parameters

The data center building has a separate cold store, energy center and fire safety station. There is an administrative center with office space for employees and clients on the territory.

Alt

We have our own 24/7 security service. The data center is equipped with a "panic button". 3 access perimeters to the entrance to the engine room. Security and video surveillance 24/7/365. Video recordings are kept for at least 90 days.

Alt

The power grid infrastructure is reserved according to the 3\2N scheme. 11 Vertiv UPSs rated at 1670 kVA. Two independent power inputs. 3 DGU FG Wilson - 2500 kVA. Autonomous operation of the UPS / DGU - more than 12 hours.

Alt

The refrigeration supply of the halls is organized according to the principle of "cold" and "hot" corridors. Reservation scheme for N+1 air conditioners. Air conditioning: The data center is equipped with precision double-circuit air conditioners (DX system).

Alt

The data centers are equipped with an addressable fire alarm system and a Vesda early fire detection system. The centralized gas fire extinguishing station has a 100% reserve of fire extinguishing agent and automatic gas fire extinguishing.

Alt

The energy, climate and network parameters of the data center are monitored around the clock in the monitoring center. Every 4 hours, the machine rooms and engineering infrastructure facilities are bypassed.

Alt

The Nubes Alto data center has 2 computer rooms for 282 racks, with a design capacity of 10 kW. Cold aisle containment systems are organized for highly loaded racks. The premises are located in containment areas.

SLA Guarantee

The detailed agreement of SLA for all customers of the “Nubes Cloud” service presents the parameters for which we are financially liable.

N+1

Redundancy of engineering systems

99,982%

Total availability

≤ 5 ms

Average SSD access time

2 inputs

power supplies for each rack

8 minutes

Maximum downtime per month

≤ 15 minutes

Incident response